Rental Cooling Towers, Sized in Tons. Ready When Downtime Isn’t an Option.
MWCTS rents towers, pumps, and heat exchangers: modular 1,000-ton Tower Tech cooling tower cells plus 400, 600 and 800-ton units, electric circulation pumps, and plate-and-frame heat exchangers, for emergencies, turnarounds, summer capacity and data centers. Our crews mobilize, install, support and demobilize, so you can focus on running your plant.
Get a quick quote
Tell us your load. We’ll call you back fast.
When you need a rental tower
From a midnight emergency to a planned rebuild, modular rental cells keep your cooling water flowing.
Emergency tower failure
A failed cell, fire or storm damage shouldn’t cut production. We bring modular rental cells to restore cooling water.
Planned turnaround
Divert water to rental towers so repairs can happen year-round, not just in winter.
Summer capacity
Add rental cells when your permanent tower can’t keep up in the heat.
Tower rebuild
Replace the capacity you take out of service, with pumps to bypass existing pumps if needed.
New construction bridge
Need cooling before the permanent tower is ready? Modules scale with the load.
Data centers
On-demand evaporative, indirect and hybrid cooling for outages, maintenance and capacity constraints.
The 1,000-ton module
One Tower Tech cell. Engineered for fast install and reliable cooling water.
| Manufacturer / style | Tower Tech Inc., counterflow |
|---|---|
| Construction | Pultruded fiberglass, galvanized steel substructure, 304 stainless hardware |
| Max flow | 3,000 gpm per module |
| Max inlet temperature | 125°F |
| Size | 35 ft 6 in L × 12 ft W × 10 ft H |
| Weight | 23,500 lb |
| Connections | Inlet 12 in, outlet 12 in, makeup 2 in, overflow 6 in |
| Electrical | 480 V, 3-phase, 60 Hz, 130 FLA |
| Fans and motors | 10 × 7.5 HP direct-drive, 900 RPM, 25,000 cfm each |
| Fill and drift | PVC CF 1900 fill, PVC CDX 80 drift eliminators |
One module equals 1,000 tons, so a 3,000-ton job is three modules. Modules join together to cover from 500 gpm to 500,000 gpm. Also available: 400, 600 and 800-ton units, electric pumps at 75, 125 and 200 HP, and plate-and-frame heat exchangers.
How it works
From the first call to demobilization, we handle the cooling so you can run the plant.
Tell us the load
Tell us your flow, temperatures and timeline.
We size it
We size the towers, pumps, and heat exchangers.
Crews mobilize
Crews mobilize, install and start up.
Support & demob
We support the rental and demobilize.
Request a rental quote
Share your cooling load, site location and dates. A rental specialist will follow up.
Send us your project details
Prefer to talk?
Call or email anytime. Rental support is available 24/7 for emergencies.